howoldisthat

Home / Furnaces and AC units / Goodman

How old is my Goodman furnace or AC?

Type the serial number from the Goodman label to see when it was built.

Example

0701009633
  • 07Year: 07 = 2007
  • 01Month: 01 = January

Built January 2007

19 years, 9 months old

In replacement window. Inside the usual 15 to 25 year lifespan, so replacement could come any time. Worth budgeting for it.

What to do now

  • Get a replacement quote now, before a breakdown in the hottest or coldest week forces a rushed choice.
  • A common rule of thumb: if the repair cost times the age in years is over 5,000, replacing usually makes more sense.
  • Ask about rebates. Many utilities and states pay toward a high-efficiency replacement.
  • Some home insurers and home buyers’ inspectors ask the age of the HVAC system. Florida 4-point inspections record it.
  • Most HVAC parts warranties run 5 to 10 years and require registration within 60 to 90 days of install. Check with the installer.
How this was read
  1. The first two digits, 07, are the year: 2007.
  2. The next two digits, 01, are the month: January.
  3. The last six digits are a running number.

Format: Goodman year and month. Sources: CPSC 2017 Goodman furnace recall (serials starting 1609 to 1612), CPSC 2013 Amana packaged unit recall (serials starting 1206 to 1210), CPSC 2014 Goodman and Amana PTAC recall, Building Intelligence Center: Goodman.

Reading a Goodman serial number

Goodman serials are 10 digits. The first two are the year and the next two are the month, so 0701 means January 2007.

Daikin bought Goodman in 2012. Goodman, Amana and Daikin ducted units share the format.

About Goodman

  • Goodman began making heating and cooling equipment in Houston in 1982. It sold Goodman as its value brand and Amana as its premium brand.
  • Most Goodman equipment moves through company-run distribution centers. The rest goes through independent distributors.
  • Since 2017 Goodman units are built at the Daikin Texas Technology Park in Waller, Texas. It replaced plants in Houston and Tennessee.
  • In 2022 the company renamed itself Daikin Comfort Technologies North America. The Goodman name stays on the equipment.

Sources: Goodman Global, Inc. Form 10-K for 2009, Daikin celebrates grand opening at new technology park, U.S. subsidiary Goodman renamed Daikin Comfort Technologies North America

Goodman year and month

Used about 1975 to today. Example: 1609123456

Goodman, Amana and Daikin ducted units have a 10-digit serial. The first two digits are the year and the next two are the month. 1609 means September 2016.

Worked example: 0701009633 was built January 2007, so it is 19 years, 9 months old as of October 2026.

Sources: CPSC 2017 Goodman furnace recall (serials starting 1609 to 1612), CPSC 2013 Amana packaged unit recall (serials starting 1206 to 1210), CPSC 2014 Goodman and Amana PTAC recall, Building Intelligence Center: Goodman

Goodman recalls

Recalls from the U.S. Consumer Product Safety Commission that name Goodman. Whether a unit is included depends on its model and build date; the checker above flags matches.

YearRecallHazard
2024Daikin FIT, Amana S-series and Goodman SD heat pumpsAfter a power cut the unit can heat the house even when set to cool.
2024Amana, Daikin and Goodman packaged unitsWrong electrical ratings on the plate can lead to wrong wiring and a fire.
2024Goodman evaporator coil drain pans above gas furnacesThe plastic drain pan can overheat, melt and catch fire.
2018Goodman, Amana and Daikin modular blowersWrong electrical info on the label can lead to undersized wiring and a fire.
2017Goodman, Amana and Daikin 80% gas furnacesThe blower motor is not grounded, which can shock someone working on it.
2017Goodman wall and ceiling air handlersThe pull-out disconnect may not cut power, which can shock someone working on it.
2008Goodman gas-electric packaged unitsWrong wiring info on the serial plate can lead to undersized wiring and a fire.
2001NOx rod gas furnaces sold in CaliforniaThese furnaces can start a fire.
1998Goodman furnaces vented with HTPV pipePlastic vent pipe can corrode, crack or come apart and leak carbon monoxide.
1996Ducane-built oil furnaces sold under many brandsThe heat exchanger can crack.